platform/x86/siemens: simatic-ipc-batt: fix bat reading in BX_21A
There was a case missing in a switch statement which lead to that model
not actually reading the GPIOs. That switch statement got simplified
now. Additionally on that model we need to initialize one pin
differently. As a drive-by finding also add a missing newline.
Fixes: 917f54340794 ("platform/x86: simatic-ipc: add CMOS battery monitoring")
Reported-by: Henning Schild <henning.schild@siemens.com>
Signed-off-by: xingtong.wu <xingtong.wu@siemens.com>
Signed-off-by: Henning Schild <henning.schild@siemens.com>
Link: https://lore.kernel.org/r/20230728083651.19747-1-henning.schild@siemens.com
Reviewed-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>