iio: hx711: add clock-frequency property in DT
Add clock-frequency property for hx711 ADC. This is the frequency of
PD_SCK.
After PD_SCK goes high DOUT is read just before PD_SCK goes down again.
This is necessary because of parasitic capacitance on the wiring.
Signed-off-by: Andreas Klinger <ak@it-klinger.de>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>