hwmon: (lm90) Add support for unsigned and signed temperatures
ADT7461 and TMP451 temperature sensors support extended temperature ranges.
If standard temperature range is selected, the temperature range is
unsigned and limited to 0 .. 127 degrees C. For TMP461, the standard
temperature range is -128000 ... 127000 degrees C. Distinguish between
the two chips by introducing a feature flag indicating if the standard
temperature range is signed or unsigned. Use the same flag for MAX6646/
MAX6647 as well since those chips also support unsigned temperatures.
Note that while the datasheet for ADT7461 suggests that the default
temperature range is unsigned, tests with a real chip suggest that this
is not the case: If the temperature offset is set to a value << 0,
the temperature register does report negative values.
Tests with real chips show that MAX6680/MAX6681 and SA56004 report
temperatures of 128 degrees C and higher as negative temperatures.
Add respective comments to the code.
Also use clamp_val() and DIV_ROUND_CLOSEST where appropriate in
calculations.