summaryrefslogtreecommitdiff
path: root/tools/perf/scripts/python/export-to-sqlite.py
diff options
context:
space:
mode:
authorViresh Kumar <viresh.kumar@linaro.org>2018-11-16 15:34:27 +0530
committerWei Xu <xuwei5@hisilicon.com>2018-11-29 10:11:21 +0000
commita7a6e2cbb4db370e84948e97adac332b59dd89d8 (patch)
treef67ae900637364d85e23a105c0572d6b3ac1d7e6 /tools/perf/scripts/python/export-to-sqlite.py
parent4c7c31104b4706023a2ce6d9aa0a3b3fe7a96f17 (diff)
arm64: dts: hi3660: Add missing cooling device properties for CPUs
The cooling device properties, like "#cooling-cells" and "dynamic-power-coefficient", should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device. Add such missing properties. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Wei Xu <xuwei5@hisilicon.com>
Diffstat (limited to 'tools/perf/scripts/python/export-to-sqlite.py')
0 files changed, 0 insertions, 0 deletions