net: pse-pd: Add power limit check
Checking only the current limit is not sufficient. According to the standard, voltage can reach up to 57V and current up to 1.92A, which exceeds the power limit described in the standard (99.9W). Add a power limit check to prevent this. Acked-by: Oleksij Rempel <o.rempel@pengutronix.de> Signed-off-by: Kory Maincent <kory.maincent@bootlin.com> Signed-off-by: Paolo Abeni <pabeni@redhat.com>