IB/hfi1: Fix a wrapping test to insure the correct timeout
The "2 * UINT_MAX" statement:
if ((u64)(ts - cce->timestamp) > 2 * UINT_MAX) {
is equivalent to:
if ((u64)(ts - cce->timestamp) > UINT_MAX - 1) {
This results in a premature timeout of the cong log entry.
Fix by using unsigned 64 bit integers, removing casts, and using
an algebraic equivalent test to avoid the "2 * UINT_MAX" issue.
Also make use of kernel API to get nanoseconds instead of
open coding.
Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Reviewed-by: Dennis Dalessandro <dennis.dalessandro@intel.com>
Signed-off-by: Mike Marciniszyn <mike.marciniszyn@intel.com>
Signed-off-by: Dennis Dalessandro <dennis.dalessandro@intel.com>
Signed-off-by: Doug Ledford <dledford@redhat.com>