summaryrefslogtreecommitdiff
path: root/arch/x86/kernel/cpu/resctrl/monitor.c
diff options
context:
space:
mode:
Diffstat (limited to 'arch/x86/kernel/cpu/resctrl/monitor.c')
-rw-r--r--arch/x86/kernel/cpu/resctrl/monitor.c921
1 files changed, 9 insertions, 912 deletions
diff --git a/arch/x86/kernel/cpu/resctrl/monitor.c b/arch/x86/kernel/cpu/resctrl/monitor.c
index a93ed7d2a160..c261558276cd 100644
--- a/arch/x86/kernel/cpu/resctrl/monitor.c
+++ b/arch/x86/kernel/cpu/resctrl/monitor.c
@@ -18,62 +18,12 @@
#define pr_fmt(fmt) "resctrl: " fmt
#include <linux/cpu.h>
-#include <linux/module.h>
-#include <linux/sizes.h>
-#include <linux/slab.h>
+#include <linux/resctrl.h>
#include <asm/cpu_device_id.h>
-#include <asm/resctrl.h>
+#include <asm/msr.h>
#include "internal.h"
-#include "trace.h"
-
-/**
- * struct rmid_entry - dirty tracking for all RMID.
- * @closid: The CLOSID for this entry.
- * @rmid: The RMID for this entry.
- * @busy: The number of domains with cached data using this RMID.
- * @list: Member of the rmid_free_lru list when busy == 0.
- *
- * Depending on the architecture the correct monitor is accessed using
- * both @closid and @rmid, or @rmid only.
- *
- * Take the rdtgroup_mutex when accessing.
- */
-struct rmid_entry {
- u32 closid;
- u32 rmid;
- int busy;
- struct list_head list;
-};
-
-/*
- * @rmid_free_lru - A least recently used list of free RMIDs
- * These RMIDs are guaranteed to have an occupancy less than the
- * threshold occupancy
- */
-static LIST_HEAD(rmid_free_lru);
-
-/*
- * @closid_num_dirty_rmid The number of dirty RMID each CLOSID has.
- * Only allocated when CONFIG_RESCTRL_RMID_DEPENDS_ON_CLOSID is defined.
- * Indexed by CLOSID. Protected by rdtgroup_mutex.
- */
-static u32 *closid_num_dirty_rmid;
-
-/*
- * @rmid_limbo_count - count of currently unused but (potentially)
- * dirty RMIDs.
- * This counts RMIDs that no one is currently using but that
- * may have a occupancy value > resctrl_rmid_realloc_threshold. User can
- * change the threshold occupancy value.
- */
-static unsigned int rmid_limbo_count;
-
-/*
- * @rmid_entry - The entry in the limbo and free lists.
- */
-static struct rmid_entry *rmid_ptrs;
/*
* Global boolean for rdt_monitor which is true if any
@@ -86,23 +36,12 @@ bool rdt_mon_capable;
*/
unsigned int rdt_mon_features;
-/*
- * This is the threshold cache occupancy in bytes at which we will consider an
- * RMID available for re-allocation.
- */
-unsigned int resctrl_rmid_realloc_threshold;
-
-/*
- * This is the maximum value for the reallocation threshold, in bytes.
- */
-unsigned int resctrl_rmid_realloc_limit;
-
#define CF(cf) ((unsigned long)(1048576 * (cf) + 0.5))
static int snc_nodes_per_l3_cache = 1;
/*
- * The correction factor table is documented in Documentation/arch/x86/resctrl.rst.
+ * The correction factor table is documented in Documentation/filesystems/resctrl.rst.
* If rmid > rmid threshold, MBM total and local values should be multiplied
* by the correction factor.
*
@@ -151,6 +90,7 @@ static const struct mbm_correction_factor_table {
};
static u32 mbm_cf_rmidthreshold __read_mostly = UINT_MAX;
+
static u64 mbm_cf __read_mostly;
static inline u64 get_corrected_mbm_count(u32 rmid, unsigned long val)
@@ -163,33 +103,6 @@ static inline u64 get_corrected_mbm_count(u32 rmid, unsigned long val)
}
/*
- * x86 and arm64 differ in their handling of monitoring.
- * x86's RMID are independent numbers, there is only one source of traffic
- * with an RMID value of '1'.
- * arm64's PMG extends the PARTID/CLOSID space, there are multiple sources of
- * traffic with a PMG value of '1', one for each CLOSID, meaning the RMID
- * value is no longer unique.
- * To account for this, resctrl uses an index. On x86 this is just the RMID,
- * on arm64 it encodes the CLOSID and RMID. This gives a unique number.
- *
- * The domain's rmid_busy_llc and rmid_ptrs[] are sized by index. The arch code
- * must accept an attempt to read every index.
- */
-static inline struct rmid_entry *__rmid_entry(u32 idx)
-{
- struct rmid_entry *entry;
- u32 closid, rmid;
-
- entry = &rmid_ptrs[idx];
- resctrl_arch_rmid_idx_decode(idx, &closid, &rmid);
-
- WARN_ON_ONCE(entry->closid != closid);
- WARN_ON_ONCE(entry->rmid != rmid);
-
- return entry;
-}
-
-/*
* When Sub-NUMA Cluster (SNC) mode is not enabled (as indicated by
* "snc_nodes_per_l3_cache == 1") no translation of the RMID value is
* needed. The physical RMID is the same as the logical RMID.
@@ -238,7 +151,7 @@ static int __rmid_read_phys(u32 prmid, enum resctrl_event_id eventid, u64 *val)
* are error bits.
*/
wrmsr(MSR_IA32_QM_EVTSEL, eventid, prmid);
- rdmsrl(MSR_IA32_QM_CTR, msr_val);
+ rdmsrq(MSR_IA32_QM_CTR, msr_val);
if (msr_val & RMID_VAL_ERROR)
return -EIO;
@@ -260,12 +173,11 @@ static struct arch_mbm_state *get_arch_mbm_state(struct rdt_hw_mon_domain *hw_do
return &hw_dom->arch_mbm_total[rmid];
case QOS_L3_MBM_LOCAL_EVENT_ID:
return &hw_dom->arch_mbm_local[rmid];
+ default:
+ /* Never expect to get here */
+ WARN_ON_ONCE(1);
+ return NULL;
}
-
- /* Never expect to get here */
- WARN_ON_ONCE(1);
-
- return NULL;
}
void resctrl_arch_reset_rmid(struct rdt_resource *r, struct rdt_mon_domain *d,
@@ -346,769 +258,6 @@ int resctrl_arch_rmid_read(struct rdt_resource *r, struct rdt_mon_domain *d,
return 0;
}
-static void limbo_release_entry(struct rmid_entry *entry)
-{
- lockdep_assert_held(&rdtgroup_mutex);
-
- rmid_limbo_count--;
- list_add_tail(&entry->list, &rmid_free_lru);
-
- if (IS_ENABLED(CONFIG_RESCTRL_RMID_DEPENDS_ON_CLOSID))
- closid_num_dirty_rmid[entry->closid]--;
-}
-
-/*
- * Check the RMIDs that are marked as busy for this domain. If the
- * reported LLC occupancy is below the threshold clear the busy bit and
- * decrement the count. If the busy count gets to zero on an RMID, we
- * free the RMID
- */
-void __check_limbo(struct rdt_mon_domain *d, bool force_free)
-{
- struct rdt_resource *r = resctrl_arch_get_resource(RDT_RESOURCE_L3);
- u32 idx_limit = resctrl_arch_system_num_rmid_idx();
- struct rmid_entry *entry;
- u32 idx, cur_idx = 1;
- void *arch_mon_ctx;
- bool rmid_dirty;
- u64 val = 0;
-
- arch_mon_ctx = resctrl_arch_mon_ctx_alloc(r, QOS_L3_OCCUP_EVENT_ID);
- if (IS_ERR(arch_mon_ctx)) {
- pr_warn_ratelimited("Failed to allocate monitor context: %ld",
- PTR_ERR(arch_mon_ctx));
- return;
- }
-
- /*
- * Skip RMID 0 and start from RMID 1 and check all the RMIDs that
- * are marked as busy for occupancy < threshold. If the occupancy
- * is less than the threshold decrement the busy counter of the
- * RMID and move it to the free list when the counter reaches 0.
- */
- for (;;) {
- idx = find_next_bit(d->rmid_busy_llc, idx_limit, cur_idx);
- if (idx >= idx_limit)
- break;
-
- entry = __rmid_entry(idx);
- if (resctrl_arch_rmid_read(r, d, entry->closid, entry->rmid,
- QOS_L3_OCCUP_EVENT_ID, &val,
- arch_mon_ctx)) {
- rmid_dirty = true;
- } else {
- rmid_dirty = (val >= resctrl_rmid_realloc_threshold);
-
- /*
- * x86's CLOSID and RMID are independent numbers, so the entry's
- * CLOSID is an empty CLOSID (X86_RESCTRL_EMPTY_CLOSID). On Arm the
- * RMID (PMG) extends the CLOSID (PARTID) space with bits that aren't
- * used to select the configuration. It is thus necessary to track both
- * CLOSID and RMID because there may be dependencies between them
- * on some architectures.
- */
- trace_mon_llc_occupancy_limbo(entry->closid, entry->rmid, d->hdr.id, val);
- }
-
- if (force_free || !rmid_dirty) {
- clear_bit(idx, d->rmid_busy_llc);
- if (!--entry->busy)
- limbo_release_entry(entry);
- }
- cur_idx = idx + 1;
- }
-
- resctrl_arch_mon_ctx_free(r, QOS_L3_OCCUP_EVENT_ID, arch_mon_ctx);
-}
-
-bool has_busy_rmid(struct rdt_mon_domain *d)
-{
- u32 idx_limit = resctrl_arch_system_num_rmid_idx();
-
- return find_first_bit(d->rmid_busy_llc, idx_limit) != idx_limit;
-}
-
-static struct rmid_entry *resctrl_find_free_rmid(u32 closid)
-{
- struct rmid_entry *itr;
- u32 itr_idx, cmp_idx;
-
- if (list_empty(&rmid_free_lru))
- return rmid_limbo_count ? ERR_PTR(-EBUSY) : ERR_PTR(-ENOSPC);
-
- list_for_each_entry(itr, &rmid_free_lru, list) {
- /*
- * Get the index of this free RMID, and the index it would need
- * to be if it were used with this CLOSID.
- * If the CLOSID is irrelevant on this architecture, the two
- * index values are always the same on every entry and thus the
- * very first entry will be returned.
- */
- itr_idx = resctrl_arch_rmid_idx_encode(itr->closid, itr->rmid);
- cmp_idx = resctrl_arch_rmid_idx_encode(closid, itr->rmid);
-
- if (itr_idx == cmp_idx)
- return itr;
- }
-
- return ERR_PTR(-ENOSPC);
-}
-
-/**
- * resctrl_find_cleanest_closid() - Find a CLOSID where all the associated
- * RMID are clean, or the CLOSID that has
- * the most clean RMID.
- *
- * MPAM's equivalent of RMID are per-CLOSID, meaning a freshly allocated CLOSID
- * may not be able to allocate clean RMID. To avoid this the allocator will
- * choose the CLOSID with the most clean RMID.
- *
- * When the CLOSID and RMID are independent numbers, the first free CLOSID will
- * be returned.
- */
-int resctrl_find_cleanest_closid(void)
-{
- u32 cleanest_closid = ~0;
- int i = 0;
-
- lockdep_assert_held(&rdtgroup_mutex);
-
- if (!IS_ENABLED(CONFIG_RESCTRL_RMID_DEPENDS_ON_CLOSID))
- return -EIO;
-
- for (i = 0; i < closids_supported(); i++) {
- int num_dirty;
-
- if (closid_allocated(i))
- continue;
-
- num_dirty = closid_num_dirty_rmid[i];
- if (num_dirty == 0)
- return i;
-
- if (cleanest_closid == ~0)
- cleanest_closid = i;
-
- if (num_dirty < closid_num_dirty_rmid[cleanest_closid])
- cleanest_closid = i;
- }
-
- if (cleanest_closid == ~0)
- return -ENOSPC;
-
- return cleanest_closid;
-}
-
-/*
- * For MPAM the RMID value is not unique, and has to be considered with
- * the CLOSID. The (CLOSID, RMID) pair is allocated on all domains, which
- * allows all domains to be managed by a single free list.
- * Each domain also has a rmid_busy_llc to reduce the work of the limbo handler.
- */
-int alloc_rmid(u32 closid)
-{
- struct rmid_entry *entry;
-
- lockdep_assert_held(&rdtgroup_mutex);
-
- entry = resctrl_find_free_rmid(closid);
- if (IS_ERR(entry))
- return PTR_ERR(entry);
-
- list_del(&entry->list);
- return entry->rmid;
-}
-
-static void add_rmid_to_limbo(struct rmid_entry *entry)
-{
- struct rdt_resource *r = resctrl_arch_get_resource(RDT_RESOURCE_L3);
- struct rdt_mon_domain *d;
- u32 idx;
-
- lockdep_assert_held(&rdtgroup_mutex);
-
- /* Walking r->domains, ensure it can't race with cpuhp */
- lockdep_assert_cpus_held();
-
- idx = resctrl_arch_rmid_idx_encode(entry->closid, entry->rmid);
-
- entry->busy = 0;
- list_for_each_entry(d, &r->mon_domains, hdr.list) {
- /*
- * For the first limbo RMID in the domain,
- * setup up the limbo worker.
- */
- if (!has_busy_rmid(d))
- cqm_setup_limbo_handler(d, CQM_LIMBOCHECK_INTERVAL,
- RESCTRL_PICK_ANY_CPU);
- set_bit(idx, d->rmid_busy_llc);
- entry->busy++;
- }
-
- rmid_limbo_count++;
- if (IS_ENABLED(CONFIG_RESCTRL_RMID_DEPENDS_ON_CLOSID))
- closid_num_dirty_rmid[entry->closid]++;
-}
-
-void free_rmid(u32 closid, u32 rmid)
-{
- u32 idx = resctrl_arch_rmid_idx_encode(closid, rmid);
- struct rmid_entry *entry;
-
- lockdep_assert_held(&rdtgroup_mutex);
-
- /*
- * Do not allow the default rmid to be free'd. Comparing by index
- * allows architectures that ignore the closid parameter to avoid an
- * unnecessary check.
- */
- if (!resctrl_arch_mon_capable() ||
- idx == resctrl_arch_rmid_idx_encode(RESCTRL_RESERVED_CLOSID,
- RESCTRL_RESERVED_RMID))
- return;
-
- entry = __rmid_entry(idx);
-
- if (resctrl_arch_is_llc_occupancy_enabled())
- add_rmid_to_limbo(entry);
- else
- list_add_tail(&entry->list, &rmid_free_lru);
-}
-
-static struct mbm_state *get_mbm_state(struct rdt_mon_domain *d, u32 closid,
- u32 rmid, enum resctrl_event_id evtid)
-{
- u32 idx = resctrl_arch_rmid_idx_encode(closid, rmid);
-
- switch (evtid) {
- case QOS_L3_MBM_TOTAL_EVENT_ID:
- return &d->mbm_total[idx];
- case QOS_L3_MBM_LOCAL_EVENT_ID:
- return &d->mbm_local[idx];
- default:
- return NULL;
- }
-}
-
-static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr)
-{
- int cpu = smp_processor_id();
- struct rdt_mon_domain *d;
- struct mbm_state *m;
- int err, ret;
- u64 tval = 0;
-
- if (rr->first) {
- resctrl_arch_reset_rmid(rr->r, rr->d, closid, rmid, rr->evtid);
- m = get_mbm_state(rr->d, closid, rmid, rr->evtid);
- if (m)
- memset(m, 0, sizeof(struct mbm_state));
- return 0;
- }
-
- if (rr->d) {
- /* Reading a single domain, must be on a CPU in that domain. */
- if (!cpumask_test_cpu(cpu, &rr->d->hdr.cpu_mask))
- return -EINVAL;
- rr->err = resctrl_arch_rmid_read(rr->r, rr->d, closid, rmid,
- rr->evtid, &tval, rr->arch_mon_ctx);
- if (rr->err)
- return rr->err;
-
- rr->val += tval;
-
- return 0;
- }
-
- /* Summing domains that share a cache, must be on a CPU for that cache. */
- if (!cpumask_test_cpu(cpu, &rr->ci->shared_cpu_map))
- return -EINVAL;
-
- /*
- * Legacy files must report the sum of an event across all
- * domains that share the same L3 cache instance.
- * Report success if a read from any domain succeeds, -EINVAL
- * (translated to "Unavailable" for user space) if reading from
- * all domains fail for any reason.
- */
- ret = -EINVAL;
- list_for_each_entry(d, &rr->r->mon_domains, hdr.list) {
- if (d->ci->id != rr->ci->id)
- continue;
- err = resctrl_arch_rmid_read(rr->r, d, closid, rmid,
- rr->evtid, &tval, rr->arch_mon_ctx);
- if (!err) {
- rr->val += tval;
- ret = 0;
- }
- }
-
- if (ret)
- rr->err = ret;
-
- return ret;
-}
-
-/*
- * mbm_bw_count() - Update bw count from values previously read by
- * __mon_event_count().
- * @closid: The closid used to identify the cached mbm_state.
- * @rmid: The rmid used to identify the cached mbm_state.
- * @rr: The struct rmid_read populated by __mon_event_count().
- *
- * Supporting function to calculate the memory bandwidth
- * and delta bandwidth in MBps. The chunks value previously read by
- * __mon_event_count() is compared with the chunks value from the previous
- * invocation. This must be called once per second to maintain values in MBps.
- */
-static void mbm_bw_count(u32 closid, u32 rmid, struct rmid_read *rr)
-{
- u64 cur_bw, bytes, cur_bytes;
- struct mbm_state *m;
-
- m = get_mbm_state(rr->d, closid, rmid, rr->evtid);
- if (WARN_ON_ONCE(!m))
- return;
-
- cur_bytes = rr->val;
- bytes = cur_bytes - m->prev_bw_bytes;
- m->prev_bw_bytes = cur_bytes;
-
- cur_bw = bytes / SZ_1M;
-
- m->prev_bw = cur_bw;
-}
-
-/*
- * This is scheduled by mon_event_read() to read the CQM/MBM counters
- * on a domain.
- */
-void mon_event_count(void *info)
-{
- struct rdtgroup *rdtgrp, *entry;
- struct rmid_read *rr = info;
- struct list_head *head;
- int ret;
-
- rdtgrp = rr->rgrp;
-
- ret = __mon_event_count(rdtgrp->closid, rdtgrp->mon.rmid, rr);
-
- /*
- * For Ctrl groups read data from child monitor groups and
- * add them together. Count events which are read successfully.
- * Discard the rmid_read's reporting errors.
- */
- head = &rdtgrp->mon.crdtgrp_list;
-
- if (rdtgrp->type == RDTCTRL_GROUP) {
- list_for_each_entry(entry, head, mon.crdtgrp_list) {
- if (__mon_event_count(entry->closid, entry->mon.rmid,
- rr) == 0)
- ret = 0;
- }
- }
-
- /*
- * __mon_event_count() calls for newly created monitor groups may
- * report -EINVAL/Unavailable if the monitor hasn't seen any traffic.
- * Discard error if any of the monitor event reads succeeded.
- */
- if (ret == 0)
- rr->err = 0;
-}
-
-static struct rdt_ctrl_domain *get_ctrl_domain_from_cpu(int cpu,
- struct rdt_resource *r)
-{
- struct rdt_ctrl_domain *d;
-
- lockdep_assert_cpus_held();
-
- list_for_each_entry(d, &r->ctrl_domains, hdr.list) {
- /* Find the domain that contains this CPU */
- if (cpumask_test_cpu(cpu, &d->hdr.cpu_mask))
- return d;
- }
-
- return NULL;
-}
-
-/*
- * Feedback loop for MBA software controller (mba_sc)
- *
- * mba_sc is a feedback loop where we periodically read MBM counters and
- * adjust the bandwidth percentage values via the IA32_MBA_THRTL_MSRs so
- * that:
- *
- * current bandwidth(cur_bw) < user specified bandwidth(user_bw)
- *
- * This uses the MBM counters to measure the bandwidth and MBA throttle
- * MSRs to control the bandwidth for a particular rdtgrp. It builds on the
- * fact that resctrl rdtgroups have both monitoring and control.
- *
- * The frequency of the checks is 1s and we just tag along the MBM overflow
- * timer. Having 1s interval makes the calculation of bandwidth simpler.
- *
- * Although MBA's goal is to restrict the bandwidth to a maximum, there may
- * be a need to increase the bandwidth to avoid unnecessarily restricting
- * the L2 <-> L3 traffic.
- *
- * Since MBA controls the L2 external bandwidth where as MBM measures the
- * L3 external bandwidth the following sequence could lead to such a
- * situation.
- *
- * Consider an rdtgroup which had high L3 <-> memory traffic in initial
- * phases -> mba_sc kicks in and reduced bandwidth percentage values -> but
- * after some time rdtgroup has mostly L2 <-> L3 traffic.
- *
- * In this case we may restrict the rdtgroup's L2 <-> L3 traffic as its
- * throttle MSRs already have low percentage values. To avoid
- * unnecessarily restricting such rdtgroups, we also increase the bandwidth.
- */
-static void update_mba_bw(struct rdtgroup *rgrp, struct rdt_mon_domain *dom_mbm)
-{
- u32 closid, rmid, cur_msr_val, new_msr_val;
- struct mbm_state *pmbm_data, *cmbm_data;
- struct rdt_ctrl_domain *dom_mba;
- enum resctrl_event_id evt_id;
- struct rdt_resource *r_mba;
- struct list_head *head;
- struct rdtgroup *entry;
- u32 cur_bw, user_bw;
-
- r_mba = resctrl_arch_get_resource(RDT_RESOURCE_MBA);
- evt_id = rgrp->mba_mbps_event;
-
- closid = rgrp->closid;
- rmid = rgrp->mon.rmid;
- pmbm_data = get_mbm_state(dom_mbm, closid, rmid, evt_id);
- if (WARN_ON_ONCE(!pmbm_data))
- return;
-
- dom_mba = get_ctrl_domain_from_cpu(smp_processor_id(), r_mba);
- if (!dom_mba) {
- pr_warn_once("Failure to get domain for MBA update\n");
- return;
- }
-
- cur_bw = pmbm_data->prev_bw;
- user_bw = dom_mba->mbps_val[closid];
-
- /* MBA resource doesn't support CDP */
- cur_msr_val = resctrl_arch_get_config(r_mba, dom_mba, closid, CDP_NONE);
-
- /*
- * For Ctrl groups read data from child monitor groups.
- */
- head = &rgrp->mon.crdtgrp_list;
- list_for_each_entry(entry, head, mon.crdtgrp_list) {
- cmbm_data = get_mbm_state(dom_mbm, entry->closid, entry->mon.rmid, evt_id);
- if (WARN_ON_ONCE(!cmbm_data))
- return;
- cur_bw += cmbm_data->prev_bw;
- }
-
- /*
- * Scale up/down the bandwidth linearly for the ctrl group. The
- * bandwidth step is the bandwidth granularity specified by the
- * hardware.
- * Always increase throttling if current bandwidth is above the
- * target set by user.
- * But avoid thrashing up and down on every poll by checking
- * whether a decrease in throttling is likely to push the group
- * back over target. E.g. if currently throttling to 30% of bandwidth
- * on a system with 10% granularity steps, check whether moving to
- * 40% would go past the limit by multiplying current bandwidth by
- * "(30 + 10) / 30".
- */
- if (cur_msr_val > r_mba->membw.min_bw && user_bw < cur_bw) {
- new_msr_val = cur_msr_val - r_mba->membw.bw_gran;
- } else if (cur_msr_val < MAX_MBA_BW &&
- (user_bw > (cur_bw * (cur_msr_val + r_mba->membw.min_bw) / cur_msr_val))) {
- new_msr_val = cur_msr_val + r_mba->membw.bw_gran;
- } else {
- return;
- }
-
- resctrl_arch_update_one(r_mba, dom_mba, closid, CDP_NONE, new_msr_val);
-}
-
-static void mbm_update_one_event(struct rdt_resource *r, struct rdt_mon_domain *d,
- u32 closid, u32 rmid, enum resctrl_event_id evtid)
-{
- struct rmid_read rr = {0};
-
- rr.r = r;
- rr.d = d;
- rr.evtid = evtid;
- rr.arch_mon_ctx = resctrl_arch_mon_ctx_alloc(rr.r, rr.evtid);
- if (IS_ERR(rr.arch_mon_ctx)) {
- pr_warn_ratelimited("Failed to allocate monitor context: %ld",
- PTR_ERR(rr.arch_mon_ctx));
- return;
- }
-
- __mon_event_count(closid, rmid, &rr);
-
- /*
- * If the software controller is enabled, compute the
- * bandwidth for this event id.
- */
- if (is_mba_sc(NULL))
- mbm_bw_count(closid, rmid, &rr);
-
- resctrl_arch_mon_ctx_free(rr.r, rr.evtid, rr.arch_mon_ctx);
-}
-
-static void mbm_update(struct rdt_resource *r, struct rdt_mon_domain *d,
- u32 closid, u32 rmid)
-{
- /*
- * This is protected from concurrent reads from user as both
- * the user and overflow handler hold the global mutex.
- */
- if (resctrl_arch_is_mbm_total_enabled())
- mbm_update_one_event(r, d, closid, rmid, QOS_L3_MBM_TOTAL_EVENT_ID);
-
- if (resctrl_arch_is_mbm_local_enabled())
- mbm_update_one_event(r, d, closid, rmid, QOS_L3_MBM_LOCAL_EVENT_ID);
-}
-
-/*
- * Handler to scan the limbo list and move the RMIDs
- * to free list whose occupancy < threshold_occupancy.
- */
-void cqm_handle_limbo(struct work_struct *work)
-{
- unsigned long delay = msecs_to_jiffies(CQM_LIMBOCHECK_INTERVAL);
- struct rdt_mon_domain *d;
-
- cpus_read_lock();
- mutex_lock(&rdtgroup_mutex);
-
- d = container_of(work, struct rdt_mon_domain, cqm_limbo.work);
-
- __check_limbo(d, false);
-
- if (has_busy_rmid(d)) {
- d->cqm_work_cpu = cpumask_any_housekeeping(&d->hdr.cpu_mask,
- RESCTRL_PICK_ANY_CPU);
- schedule_delayed_work_on(d->cqm_work_cpu, &d->cqm_limbo,
- delay);
- }
-
- mutex_unlock(&rdtgroup_mutex);
- cpus_read_unlock();
-}
-
-/**
- * cqm_setup_limbo_handler() - Schedule the limbo handler to run for this
- * domain.
- * @dom: The domain the limbo handler should run for.
- * @delay_ms: How far in the future the handler should run.
- * @exclude_cpu: Which CPU the handler should not run on,
- * RESCTRL_PICK_ANY_CPU to pick any CPU.
- */
-void cqm_setup_limbo_handler(struct rdt_mon_domain *dom, unsigned long delay_ms,
- int exclude_cpu)
-{
- unsigned long delay = msecs_to_jiffies(delay_ms);
- int cpu;
-
- cpu = cpumask_any_housekeeping(&dom->hdr.cpu_mask, exclude_cpu);
- dom->cqm_work_cpu = cpu;
-
- if (cpu < nr_cpu_ids)
- schedule_delayed_work_on(cpu, &dom->cqm_limbo, delay);
-}
-
-void mbm_handle_overflow(struct work_struct *work)
-{
- unsigned long delay = msecs_to_jiffies(MBM_OVERFLOW_INTERVAL);
- struct rdtgroup *prgrp, *crgrp;
- struct rdt_mon_domain *d;
- struct list_head *head;
- struct rdt_resource *r;
-
- cpus_read_lock();
- mutex_lock(&rdtgroup_mutex);
-
- /*
- * If the filesystem has been unmounted this work no longer needs to
- * run.
- */
- if (!resctrl_mounted || !resctrl_arch_mon_capable())
- goto out_unlock;
-
- r = resctrl_arch_get_resource(RDT_RESOURCE_L3);
- d = container_of(work, struct rdt_mon_domain, mbm_over.work);
-
- list_for_each_entry(prgrp, &rdt_all_groups, rdtgroup_list) {
- mbm_update(r, d, prgrp->closid, prgrp->mon.rmid);
-
- head = &prgrp->mon.crdtgrp_list;
- list_for_each_entry(crgrp, head, mon.crdtgrp_list)
- mbm_update(r, d, crgrp->closid, crgrp->mon.rmid);
-
- if (is_mba_sc(NULL))
- update_mba_bw(prgrp, d);
- }
-
- /*
- * Re-check for housekeeping CPUs. This allows the overflow handler to
- * move off a nohz_full CPU quickly.
- */
- d->mbm_work_cpu = cpumask_any_housekeeping(&d->hdr.cpu_mask,
- RESCTRL_PICK_ANY_CPU);
- schedule_delayed_work_on(d->mbm_work_cpu, &d->mbm_over, delay);
-
-out_unlock:
- mutex_unlock(&rdtgroup_mutex);
- cpus_read_unlock();
-}
-
-/**
- * mbm_setup_overflow_handler() - Schedule the overflow handler to run for this
- * domain.
- * @dom: The domain the overflow handler should run for.
- * @delay_ms: How far in the future the handler should run.
- * @exclude_cpu: Which CPU the handler should not run on,
- * RESCTRL_PICK_ANY_CPU to pick any CPU.
- */
-void mbm_setup_overflow_handler(struct rdt_mon_domain *dom, unsigned long delay_ms,
- int exclude_cpu)
-{
- unsigned long delay = msecs_to_jiffies(delay_ms);
- int cpu;
-
- /*
- * When a domain comes online there is no guarantee the filesystem is
- * mounted. If not, there is no need to catch counter overflow.
- */
- if (!resctrl_mounted || !resctrl_arch_mon_capable())
- return;
- cpu = cpumask_any_housekeeping(&dom->hdr.cpu_mask, exclude_cpu);
- dom->mbm_work_cpu = cpu;
-
- if (cpu < nr_cpu_ids)
- schedule_delayed_work_on(cpu, &dom->mbm_over, delay);
-}
-
-static int dom_data_init(struct rdt_resource *r)
-{
- u32 idx_limit = resctrl_arch_system_num_rmid_idx();
- u32 num_closid = resctrl_arch_get_num_closid(r);
- struct rmid_entry *entry = NULL;
- int err = 0, i;
- u32 idx;
-
- mutex_lock(&rdtgroup_mutex);
- if (IS_ENABLED(CONFIG_RESCTRL_RMID_DEPENDS_ON_CLOSID)) {
- u32 *tmp;
-
- /*
- * If the architecture hasn't provided a sanitised value here,
- * this may result in larger arrays than necessary. Resctrl will
- * use a smaller system wide value based on the resources in
- * use.
- */
- tmp = kcalloc(num_closid, sizeof(*tmp), GFP_KERNEL);
- if (!tmp) {
- err = -ENOMEM;
- goto out_unlock;
- }
-
- closid_num_dirty_rmid = tmp;
- }
-
- rmid_ptrs = kcalloc(idx_limit, sizeof(struct rmid_entry), GFP_KERNEL);
- if (!rmid_ptrs) {
- if (IS_ENABLED(CONFIG_RESCTRL_RMID_DEPENDS_ON_CLOSID)) {
- kfree(closid_num_dirty_rmid);
- closid_num_dirty_rmid = NULL;
- }
- err = -ENOMEM;
- goto out_unlock;
- }
-
- for (i = 0; i < idx_limit; i++) {
- entry = &rmid_ptrs[i];
- INIT_LIST_HEAD(&entry->list);
-
- resctrl_arch_rmid_idx_decode(i, &entry->closid, &entry->rmid);
- list_add_tail(&entry->list, &rmid_free_lru);
- }
-
- /*
- * RESCTRL_RESERVED_CLOSID and RESCTRL_RESERVED_RMID are special and
- * are always allocated. These are used for the rdtgroup_default
- * control group, which will be setup later in resctrl_init().
- */
- idx = resctrl_arch_rmid_idx_encode(RESCTRL_RESERVED_CLOSID,
- RESCTRL_RESERVED_RMID);
- entry = __rmid_entry(idx);
- list_del(&entry->list);
-
-out_unlock:
- mutex_unlock(&rdtgroup_mutex);
-
- return err;
-}
-
-static void dom_data_exit(struct rdt_resource *r)
-{
- mutex_lock(&rdtgroup_mutex);
-
- if (!r->mon_capable)
- goto out_unlock;
-
- if (IS_ENABLED(CONFIG_RESCTRL_RMID_DEPENDS_ON_CLOSID)) {
- kfree(closid_num_dirty_rmid);
- closid_num_dirty_rmid = NULL;
- }
-
- kfree(rmid_ptrs);
- rmid_ptrs = NULL;
-
-out_unlock:
- mutex_unlock(&rdtgroup_mutex);
-}
-
-static struct mon_evt llc_occupancy_event = {
- .name = "llc_occupancy",
- .evtid = QOS_L3_OCCUP_EVENT_ID,
-};
-
-static struct mon_evt mbm_total_event = {
- .name = "mbm_total_bytes",
- .evtid = QOS_L3_MBM_TOTAL_EVENT_ID,
-};
-
-static struct mon_evt mbm_local_event = {
- .name = "mbm_local_bytes",
- .evtid = QOS_L3_MBM_LOCAL_EVENT_ID,
-};
-
-/*
- * Initialize the event list for the resource.
- *
- * Note that MBM events are also part of RDT_RESOURCE_L3 resource
- * because as per the SDM the total and local memory bandwidth
- * are enumerated as part of L3 monitoring.
- */
-static void l3_mon_evt_init(struct rdt_resource *r)
-{
- INIT_LIST_HEAD(&r->evt_list);
-
- if (resctrl_arch_is_llc_occupancy_enabled())
- list_add_tail(&llc_occupancy_event.list, &r->evt_list);
- if (resctrl_arch_is_mbm_total_enabled())
- list_add_tail(&mbm_total_event.list, &r->evt_list);
- if (resctrl_arch_is_mbm_local_enabled())
- list_add_tail(&mbm_local_event.list, &r->evt_list);
-}
-
/*
* The power-on reset value of MSR_RMID_SNC_CONFIG is 0x1
* which indicates that RMIDs are configured in legacy mode.
@@ -1192,51 +341,6 @@ static __init int snc_get_config(void)
return ret;
}
-/**
- * resctrl_mon_resource_init() - Initialise global monitoring structures.
- *
- * Allocate and initialise global monitor resources that do not belong to a
- * specific domain. i.e. the rmid_ptrs[] used for the limbo and free lists.
- * Called once during boot after the struct rdt_resource's have been configured
- * but before the filesystem is mounted.
- * Resctrl's cpuhp callbacks may be called before this point to bring a domain
- * online.
- *
- * Returns 0 for success, or -ENOMEM.
- */
-int __init resctrl_mon_resource_init(void)
-{
- struct rdt_resource *r = resctrl_arch_get_resource(RDT_RESOURCE_L3);
- int ret;
-
- if (!r->mon_capable)
- return 0;
-
- ret = dom_data_init(r);
- if (ret)
- return ret;
-
- l3_mon_evt_init(r);
-
- if (resctrl_arch_is_evt_configurable(QOS_L3_MBM_TOTAL_EVENT_ID)) {
- mbm_total_event.configurable = true;
- resctrl_file_fflags_init("mbm_total_bytes_config",
- RFTYPE_MON_INFO | RFTYPE_RES_CACHE);
- }
- if (resctrl_arch_is_evt_configurable(QOS_L3_MBM_LOCAL_EVENT_ID)) {
- mbm_local_event.configurable = true;
- resctrl_file_fflags_init("mbm_local_bytes_config",
- RFTYPE_MON_INFO | RFTYPE_RES_CACHE);
- }
-
- if (resctrl_arch_is_mbm_local_enabled())
- mba_mbps_default_event = QOS_L3_MBM_LOCAL_EVENT_ID;
- else if (resctrl_arch_is_mbm_total_enabled())
- mba_mbps_default_event = QOS_L3_MBM_TOTAL_EVENT_ID;
-
- return 0;
-}
-
int __init rdt_get_mon_l3_config(struct rdt_resource *r)
{
unsigned int mbm_offset = boot_cpu_data.x86_cache_mbm_width_offset;
@@ -1284,13 +388,6 @@ int __init rdt_get_mon_l3_config(struct rdt_resource *r)
return 0;
}
-void resctrl_mon_resource_exit(void)
-{
- struct rdt_resource *r = resctrl_arch_get_resource(RDT_RESOURCE_L3);
-
- dom_data_exit(r);
-}
-
void __init intel_rdt_mbm_apply_quirk(void)
{
int cf_index;